Skip to Content
  • Follow us
  • +44 (0) 330 127 7928
Zikodrive
  • 0
  • Sign in
  • Contact Us
  • Services

    Services


    Custom Motor Controller Design Contract Electronic Manufacturing (CEM)
  • Applications

    Applications


    Pump Controllers and DrivesHigh Speed / High Frequency Inverters Integrated Motor Controllers Motor Controllers for Low Inductance Motors Case Studies
  • Knowledge

    Knowledge


    Technical Articles What is a motor controller? Frequently Asked Questions (FAQs) Case Studies
  • About

    About Us


    Company History Our Team Careers Latest News

    Capability


    Manufacturing Capability Technology Research and DevelopmentResearch and Development Collaboration

    Quality and Assurance


    Quality

    Contact Us


    Contact our Sales Team Distribution / Agent Enquiries
  • Support

    Support


    Downloads
    Follow us
  • Products
Zikodrive
  • 0
    • Services
    • Applications
    • Knowledge
    • About
    • Support
    • Products
  • +44 (0) 330 127 7928
  • Follow us
  • Sign in
  • Contact Us
  • All Blogs
  • Case Studies
  • Understanding Pole Pairs in BLDC and PMSM Motors
  • Understanding Pole Pairs in BLDC and PMSM Motors

    16 October 2026 by
    Phil Bates

    What is a pole pair?

    In a brushless DC (BLDC) or permanent magnet synchronous motor (PMSM), the rotor carries permanent magnets arranged with alternating north and south poles around its circumference. A pole pair is one north pole and one south pole. The number of pole pairs, usually written P, is half the number of magnet poles: a 4-pole rotor has P = 2 and an 8-pole rotor has P = 4. The stator winding is arranged to produce a rotating field with the same number of poles.

    Motor datasheets are not consistent about this. Some quote poles, some quote pole pairs, and some say "poles" when they mean pairs. It is always worth confirming which one you have before configuring a controller, for reasons covered below.

    Figure 1 — Permanent magnet rotors with one, two and four pole pairs
    Rotor magnet arrangements for 2-pole, 4-pole and 8-pole permanent magnet rotors N S 2-pole rotor P = 1 N S N S 4-pole rotor P = 2 N S N S N S N S 8-pole rotor P = 4

    Electrical angle and mechanical angle

    A motor controller does not drive the shaft angle directly. It drives the stator currents through electrical cycles, and each electrical cycle advances the rotor by one pole pair. A motor with P pole pairs therefore completes P electrical cycles for every mechanical revolution of the shaft:

    θe = P × θm
    fe = (P × n) / 60
    θe = electrical angle  ·  θm = mechanical angle  ·  fe = electrical frequency (Hz)  ·  n = shaft speed (rpm)  ·  P = pole pairs
    Figure 2 — Back-EMF over one shaft revolution: one pole pair compared with four
    Back-EMF over one mechanical revolution for a motor with one pole pair and one with four pole pairs P = 1 1 electrical cycle P = 4 4 electrical cycles 0° 90° 180° 270° 360° Mechanical angle (one shaft revolution)
    No slip. BLDC and PMSM motors are synchronous machines. In steady state the rotor turns at exactly fe / P revolutions per second, locked to the field the controller creates. Unlike an induction motor there is no slip, so shaft speed is set entirely by the electrical frequency and the pole-pair count.

    Why pole pairs matter to the motor controller

    Commutation and Hall sensors

    With six-step (trapezoidal) commutation, the controller changes the phase switching pattern six times per electrical cycle, which is 6 × P times per shaft revolution. Three Hall sensors likewise produce six state changes per electrical cycle, so an 8-pole motor (P = 4) gives 24 Hall edges per revolution. That finer resolution is one reason Hall feedback works well on high-pole-count motors at low speed.

    Electrical frequency and controller limits

    Because electrical frequency rises with both speed and pole count, the pole count largely decides how hard the controller has to work. With field-oriented control (FOC), the current loop typically runs once per PWM period, and the controller needs enough PWM periods within each electrical cycle to shape the current accurately. As a rule of thumb, 10 to 20 or more PWM periods per electrical cycle is comfortable. Below that, current ripple, torque ripple and position-estimation error increase quickly.

    Figure 3 — Electrical frequency against shaft speed for different pole-pair counts
    Electrical frequency against shaft speed for 1, 2, 4 and 7 pole pairs 0 1,000 2,000 3,000 4,000 0 10,000 20,000 30,000 Shaft speed (rpm) Electrical frequency (Hz) P = 1 P = 2 P = 4 P = 7

    For example, a motor with 8 pole pairs at 30,000 rpm runs at 4 kHz electrical. At a 20 kHz PWM frequency that leaves only five PWM periods per electrical cycle. The same speed on a one-pole-pair motor is 500 Hz, giving 40 PWM periods per cycle. This is why high-speed spindles, blowers and compressors usually use one or two pole pairs, and why they need controllers designed for high electrical frequencies.

    Iron losses

    Stator core losses rise with electrical frequency, with eddy-current loss increasing roughly with its square. At the same shaft speed, a higher-pole-count motor therefore tends to have higher iron losses. Thinner laminations and lower-loss electrical steels help, but this becomes a real design constraint at high speed.

    Position sensors and getting the setting right

    With FOC and an encoder, the controller calculates electrical angle from shaft angle using θe = P × θm. If the pole-pair setting is wrong, the calculated angle drifts away from the true rotor position during each revolution, and the motor vibrates, draws excessive current or will not run at all. In sensorless operation, the controller derives speed from electrical frequency, so entering the pole count (2P) where it expects pole pairs makes the motor run at twice the commanded speed. Checking this one parameter solves a surprising number of commissioning problems.

    Electrical frequency calculator

    Enter the motor's speed and pole pairs and the controller's PWM frequency to see the electrical frequency and how much headroom the controller has.

    Pole pairs and electrical frequency

    Shaft speed 3,000 rpm
    Pole pairs (P) 4 (8-pole)
    PWM frequency 20 kHz
    Electrical frequency
    200 Hz
    Commutation steps per second (six-step)
    1,200
    Hall edges per shaft revolution
    24
    PWM periods per electrical cycle
    100
    Comfortable

    Headroom bands are a rule of thumb: 20 or more is comfortable, 10 to 20 is tight, and below 10 needs a controller designed for high electrical frequency.

    Torque, back-EMF and motor design

    For a PMSM, electromagnetic torque is Te = &frac32; × P × λpm × iq, where λpm is the magnet flux linkage and iq is the torque-producing current. For a given flux linkage, more pole pairs means more torque per amp, and both the torque constant (Kt) and back-EMF constant (Ke) scale with P.

    In practice it is not free. As the pole count rises, each magnet covers a smaller arc, so the flux per pole falls and leakage between neighbouring magnets increases. The benefit is that less flux per pole allows thinner back iron in the rotor and stator. That is why high-pole-count motors tend to be short and large in diameter, as in outrunners, hub motors and robot joints, giving high torque at low speed without a gearbox. Low pole counts suit compact rotors that need to spin fast.

    Pole and slot combinations

    The pole count also has to suit the number of stator slots. Combinations are often written as slots and magnet poles, for example 12N14P for 12 slots and 14 poles. Note that the P in this notation means poles, not pole pairs, which is another common source of confusion: a 12N14P motor has 7 pole pairs.

    Cogging torque, the detent you feel when turning an unpowered motor by hand, repeats a number of times per revolution equal to the least common multiple of the slot and pole counts. The higher that number, the smaller the cogging tends to be. A 9-slot, 6-pole motor has 18 cogging periods per revolution, while a 12-slot, 14-pole motor has 84 and usually runs far more smoothly at low speed.

    Typical pole-pair counts by application

    ApplicationTypical pole pairsReason
    High-speed spindles, blowers and compressors1–2Keeps electrical frequency manageable at tens of thousands of rpm
    Pumps and fans2–4Balances speed, efficiency and controller demands
    Industrial servo motors3–5Good torque density with smooth low-speed control
    Drone and hobby outrunners6–14High torque at low speed for direct propeller drive
    Hub motors, robot joints and gimbals7–25+Direct drive at low speed without a gearbox
    Direct-drive wind generators50+Generating at blade speed without a gearbox

    Typical ranges only; individual designs vary.

    Key takeaway: pole pairs set the ratio between electrical frequency and shaft speed. More pole pairs give more torque per amp and suit low-speed direct drive, but raise the electrical frequency the controller has to handle and the iron losses the motor has to absorb. Matching pole count, speed range and controller capability is one of the most important decisions in any BLDC or PMSM drive.
    Matching a motor and controller at high speed or high pole count? See our custom motor controller design service or talk to our team.


    in Case Studies

    Read Next
    Sensorless Brushless DC Control for a Hydraulic Actuator

    • Home
    • •
    • About us
    • •
    • Products
    • •
    • Terms of Services
    Copyright © Round Bank Engineering Ltd - all rights reserved 
    Terms and Conditions
    Privacy Policy
    Powered by Odoo - The #1 Open Source eCommerce

    We use cookies to provide you a better user experience on this website. Cookie Policy

    Only essentials I agree